Manufacturer | Brake/ClutchManufacturer Model No. | Magtorx DPS |
Voltage [V] | Rated Current [A] | Model/Spec. |
API Deltran | 6, 12, 24, 30, 90V coil voltageMagtorx current regulated power supplies can be used for any model of API Deltran brakes or clutches. To select proper power supply for API Deltran brake or clutch refer to the power supply Product Specification page or consult with a Magtorx application engineer. Also check the capability of Current Scaling, Soft Start and Soft Stop. | 6V 12V 24V 28/30V 48V 60V90V | Up to 7.50AUp to 3.90AUp to 2.00AUp to 1.60AUp to 1.00AUp to .75AUp to .50A | 
ON DPS OP DPS EC DPS EO DPS |
Electroid | 6, 12, 24, 30, 90V coil voltageMagtorx current regulated power supplies can be used for any model of Electroid brakes or clutches. To select proper power supply for Electroids brake or clutch refer to the power supply Product Specification page or consult with a Magtorx application engineer. Also check the capability of Current Scaling, Soft Start and Soft Stop. | 6V 12V 24V 28/30V 48V 60V90V | Up to 7.50AUp to 3.90AUp to 2.00AUp to 1.60AUp to 1.00AUp to .75AUp to .50A | 
ON DPS OP DPS EC DPS EO DPS |
Inertial Dynamics(Dynacorp) | 6, 12, 24, 30, 90V coil voltageMagtorx current regulated power supplies can be used for any model of Inertial Dynamics (Dynacorp) brakes or clutches. To select proper power supply for Inertial Dynamics (Dynacorp brake or clutch refer to the power supply Product Specification page or consult with a Magtorx application engineer. Also check the capability of Current Scaling, Soft Start and Soft Stop. | 6V 12V 24V 28/30V 48V 60V90V | Up to 7.50AUp to 3.90AUp to 2.00AUp to 1.60AUp to 1.00AUp to .75AUp to .50A | 
ON DPS OP DPS EC DPS EO DPS |
Ogura | 24V coil voltageFRICTION BRAKES: Model PMB; (example: PMB-11)FRICTION CLUTCHES: AMC; AMU(example: AMC80; AMU40)6, 12, 24, 30, 90V coil voltageMagtorx current regulated power supplies can also be used for any other model of Ogura brakes or clutches. To select proper power supply for Ogura brake or clutch refer to the power supply Product Specification page or consult with a Magtorx application engineer. Also check the capability of Current Scaling, Soft Start and Soft Stop. | 24V 6V 12V 24V 28/30V 48V 60V90V | Up to 2.00A Up to 7.50AUp to 3.90AUp to 2.00AUp to 1.60AUp to 1.00AUp to .75AUp to .50A | 
ON DPS OP DPS EC DPS EO DPS |
SDP/SI Catalog | 6, 12, 24, 30, 90V coil voltageMagtorx current regulated power supplies can be used for current-torque control for any model of SDP/SI catalog brakes or clutches. To select proper power supply for SDP/SI catalog brake or clutch refer to the power supply Product Specification page or consult with a Magtorx application engineer. Also check the capability of Current Scaling, Soft Start and Soft Stop. | 6V 12V 24V 28/30V 48V 60V90V | Up to 7.50AUp to 3.90AUp to 2.00AUp to 1.60AUp to 1.00AUp to .75AUp to .50A | 
ON DPS OP DPS EC DPS EO DPS |
WarnerElectric | 24V coil voltageELECTRO SINGLE AND DUAL DISC BRAKES: 10-0; 10-10; 13-0; 13-13; 15-0; 15-15; 20-0; 20-20 Series (example: 10-10-4; 20-0-5 ) Note: for brakes supplied with more than 6 coils, two 24V power supplies can be used. Both power supplies can be controlled by the same control signal. 6, 12, 24, 28/30, 90V coil voltageMagtorx current regulated power supplies can also be used for any other model of Warner Electric brakes or clutches. For all Warner Electric brakes and clutches requiring precision current control refer to the power supply Product Specification page or consult with a Magtorx application engineer. Also check the capability of Current Scaling, Soft Start and Soft Stop. | 24V 6V 12V 24V 28/30V 48V 60V90V | Up to 2.00A Up to 7.50AUp to 3.90AUp to 2.00AUp to 1.60AUp to 1.00AUp to .75AUp to .50A | 
ON DPS OP DPS EC DPS EO DPS |
W. M. Berg | 6, 12, 24, 28/30, 90V coil voltageMagtorx current regulated power supplies can be used for any model of W. M. Berg brakes or clutches. For all W. M. Berg brakes and clutches requiring precision current control refer to the power supply Product Specification page or consult with a Magtorx application engineer. Also check the capability of Current Scaling, Soft Start and Soft Stop. | 6V 12V 24V 28/30V 48V 60V90V | Up to 7.50AUp to 3.90AUp to 2.00AUp to 1.60AUp to 1.00AUp to .75AUp to .50A | 
ON DPS OP DPS EC DPS EO DPS |