| Manufacturer | Brake/ClutchManufacturer Model No. | Magtorx DPS |
Voltage [V] | Rated Current [A] | Model Specification |
Andantex, Merobel & Moback | 12V coil voltageMAGNETIC PARTICLE BRAKES - FAS, FRAS, FAT, FRAT & FRATO Family (example: FRAT 1200, FRATO 2002) MAGNETIC PARTICLE CLUTCHES - EFAS, EAT, ERAT Family(example: EAFS 50)24V coil voltageMAGNETIC PARTICLE BRAKES - FAT, FRAT & FRATO Family (example: FRAT 120)All 24V HYSTERESIS CLUTCHES - EFAS, EAT, ERAT Family(example: EAFS 10)For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 12V 24V | Up to 3.90A Up to 2.00A | 
ON DPS OP DPS EC DPS EO DPS |
API Deltran | All models - Magtorx Current Regulated Power Supply can be used for all models of Deltran’s brakes and clutches. Refer to the power supply specification to assure that the specific power supply is suitable for the chosen API Deltran's brake or clutch. | 24V 90V | Up to 2.00A Up to .50A | 
ON DPS OP DPS EC DPS EO DPS |
Electroid | 24V coil voltageALL MAGNETIC PARTICLE BRAKES - EPB; TC-BEC; EPCB Models (example: EPB-120-12S-24; EPCB-155-8-24) ALL MAGNETIC PARTICLE CLUTCHES - EPC; TS-SEC and TS-SBEC Models (example: EPC-15-8-24; TS-BEC-26C-8) 90V coil voltageALL MAGNETIC PARTICLE BRAKES - EPB; TC-BEC; EPCB Models (example: EPB-120-12S-90; EPCB-155-8-90) ALL MAGNETIC PARTICLE CLUTCHES - EPC; TS-SEC and TS-SBEC Models (example: EPC-15-8-90) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 24V 90V | Up to 2.00A Up to .50A | v
ON DPS OP DPS EC DPS EO DPS |
Lord | 12V coil voltageMAGNETIC PARTICLE BRAKES - MR; MRB Family (example: MRB-2107…) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 12V | Up to 3.90A | 
ON DPS OP DPS EC DPS EO DPS |
Magneta Co. & Brakeclutch, LLC | 24V coil voltageALL MAGNETIC PARTICLE BRAKES - Type 14.512 (Size 01; 02; 04; 08; 16; 32, and others) (example: 14.512.16…) ALL MAGNETIC PARTICLE CLUTCHES - Type 14.501, 14.502 (Size 01; 02; 04; 08; 16; 32, and others) (example: 14.501.32.…) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 24V | Up to 2.00A | 
ON DPS OP DPS EC DPS EO DPS |
Magne Corp. | 90V coil voltageALL MAGNETIC PARTICLE BRAKES - 5MB90; 10MB90; 25MB90; 50MB90 convection, forced air or water cooled (example: 10MBW90B-20; 25MB90S; 50MBA90S) ALL MAGNETIC PARTICLE CLUTCHES - 1MC90; 5MC90; 7MC90; 10MC90; 50MC90 convection, forced air or water cooled (example: 10MCA90B-20; 10MCW90B-20; 50MC90B-20) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 90V | Up to .50A | 
ON DPS OP DPS EC DPS EO DPS |
MagPowr Corp. | 90V coil voltageALL MAGNETIC PARTICLE BRAKES - B; Vertical B (B-7V & B-20V); HDB; Double C (CCB); Global (GBA/B/C & GBAM/BM/CM) convection, forced air or water cooled (example: B-25A; HDB-100WA; B20V; CCB 625; GBCM) ALL MAGNETIC PARTICLE CLUTCHES - C; Double C (CCC) convection, forced air or water cooled (example: C-3A; C-10W; C-50FA; CCC 875) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 90V | Up to .50A | 
ON DPS OP DPS EC DPS EO DPS |
Mobac | 12V coil voltageMAGNETIC PARTICLE BRAKES - FAS, FRAS, FAT, FRAT & FRATO Family (example: FRAT 1200, FRATO 2002) MAGNETIC PARTICLE CLUTCHES - EFAS, EAT, ERAT Family (example: EAFS 50) 24V coil voltageMAGNETIC PARTICLE BRAKES - FAT, FRAT & FRATO Family (example: FRAT 120) MAGNETIC PARTICLE CLUTCHES - EFAS, EAT, ERAT Family (example: EAFS 10) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 12V 24V | Up to 3.90A Up to 2.00A | 
ON DPS OP DPS EC DPS EO DPS |
Ogura Industrial Corp. | 24V coil voltageALL MAGNETIC PARTICLE BRAKES - Model OP; OPL and OPB-N (example: OPB80N) ALL MAGNETIC PARTICLE CLUTCHES - OP; OPC (example: OPC40) For model PC/PB consult with a Magtorx application engineer For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 24V | Up to 2.00A | 
ON DPS OP DPS EC DPS EO DPS |
PlacidIndustries Inc. &Huco Co. | 6V coil voltageALL MAGNETIC PARTICLE BRAKES and CLUTCHES - B and C Series (example: B150; C130) 12Vcoil voltageALL MAGNETIC PARTICLE BRAKES and CLUTCHES - B and C Series (example: B150; C130) 24V coil voltageALL MAGNETIC PARTICLE BRAKES and CLUTCHES - B, B-H and C Series (example: B150; C130) 90V coil voltageALL MAGNETIC PARTICLE BRAKES and CLUTCHES - B and C Series (example: B150; C130) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 6V 12V 24V 90V | Up to 7.50A Up to 3.90A Up to 2.00A Up to .50A | 
ON DPS OP DPS EC DPS EO DPS |
PrecisionTork | 24V coil voltageALL MAGNETIC PARTICLE BRAKES and CLUTCHES - MPB and MPC Models (example: MPB120; MPC70) 90V coil voltageALL MAGNETIC PARTICLE BRAKES and CLUTCHES - MPB and MPC Models (example: MPB240; MPC70) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 24V 90V | Up to 2.00A Up to .50A | 
ON DPS OP DPS EC DPS EO DPS |
SDP/SICatalog | 24V coil voltageAll HYSTERESIS BRAKES - S90MPA-B SERIES (example: SMPA-B52D75S) All HYSTERESIS CLUTCHES -S90MPA-C SERIES (example: SMPA-C45D75) Refer to the power supply specification to assure that the specific power supply is suitable for a chosen brake or clutch. | 24V | Up to 2.00A | 
ON DPS OP DPS EC DPS EO DPS |
WarnerElectric | 24V coil voltageMAGNETIC PARTICLE BRAKES - MPB; POB; PRB-H; PRB-HF; PRB-S;PRB-SF; PTB Models (example: MPB120) MAGNETIC PARTICLE CLUTCHES - MPC; PMC-A3; MPCPHC-RPOC Models (example: MPC120) 90V coil voltageMAGNETIC PARTICLE BRAKES and CLUTCHES - MPB and MPC Models (example: MPB240; MPC70) For additional brakes and clutches not listed above that require precision current control refer to the power supply specification to assure that the specific power supply is suitable for the chosen brake or clutch. | 24V 90V | Up to 2.00A Up to .50A | 
ON DPS OP DPS EC DPS EO DPS |